Based on infrared photoacoustic spectroscopy technology, DKG-ONE Photoacoustic Gas Analyzer combines the unique light source and detector which is a patented enhanced cantilever beam optical microphone with ultra-high sensitivity. It can be widely applied
Transformer online monitoring and fault diagnosis technology is of great significance to improve the safety and stability of the power system.
DK-BSC 3001 series battery spontaneous combustion monitoring system from Duke Technology integrates ultraviolet absorption spectrum, infrared photoacoustic spectrum, cavity enhanced absorption spectrum, Fourier infrared spectrum, tunable semiconductor abs
Ventilation system is to monitor the concentration change of tracer gas to calculate the ventilation efficiency.
SF6 is widely used in GIS as a good insulation and interruption gas.
In oil or gas extraction processes, optimizing production methods is crucial. It is particularly important to accurately understand the flow rates, volumes, flow patterns, and cumulative trends of solid particles during extraction. The sand monitoring sys
The sand monitoring system from Duke integrates the measurement of fluid patterns, flow rate, instantaneous flow, and cumulative flow of sand. It is a low-cost, real-time monitoring system for predicting the flow patterns and cumulative trends of sand.
The sand monitoring system from Duke integrates the measurement of fluid patterns, flow rate, instantaneous flow, and cumulative flow of sand. It is a low-cost, real-time monitoring system for predicting the flow patterns and cumulative trends of sand.
When sand enters the wells or pipelines during the extraction process, it is essential to ensure the clear passage of the sand. Real-time monitoring of the flow rate, instantaneous flow, cumulative flow, erosion rate, and movement patterns of sand/solid p
The sand monitoring system from Duke integrates the measurement of fluid patterns, flow rate, instantaneous flow, and cumulative flow of sand. It is a low-cost, real-time monitoring system for predicting the flow patterns and cumulative trends of sand.
The Duke pigging indicator uses passive acoustic (ultrasonic) technology to sense the pig traveling through the pipeline, utilizing a built-in Lock Frequency Digital Signal Processor (LPDSP).
The DK-SA 830 Gas-Solid Separator operates on the principles of centrifugal sedimentation and density differences. When the fluid enters the separator tangentially at a certain pressure, it generates intense rotational motion.
Based on echo sensing technology, the Duke Non-intrusive acoustic pipe thickness monitor uses high-frequency sound waves generated by piezoelectric transducers to pass through materials.
The innovative DK-SA 850 downhole sand monitoring device features a new tool architecture, integrating advanced sensor design, signal processing technology, and analytical algorithms to accurately detect downhole sand ingress points and assess sand produc
DK-SA 860-S Series Vibration Sensor can connect to analog signal output of acceleration, speed, displacement sensors, can calculate speed and displacement data based on acceleration data, features include different sensor parameter settings, data acquisit
CARBOTEC continuously measures the content of dissolved carbon dioxide in liquids. Designed for applications that require maximum sensitivity and high accuracy, this device is used in the food and beverage industry all around the world. Breweries and soft drink manufacturers determine and control the CO2 content in their products with CARBOTEC. For measuring carbon dioxide, the carbonated liquid flows through the sensor head (measurement chamber). Several times per minute the chamber is closed and its volume is rapidly increased. This expansion generates a gas phase in the chamber. The large partial pressure difference of CO2 forces the carbon dioxide out of the liquid into the gas. This fundamental scientific principle is described by “Henry’s Law”. Within seconds pressure equilibrium in the measurement chamber is reached. The equilibrium pressure differs from the pressure of a non-carbonated liquid according to the volume of dissolved CO2 in the sample. Thus, the CO2 content can be determined. Any temperature drifts of the measured signal are automatically compensated by an internal Pt100 sensor. After the measurement the sample is completely returned to the product without any loss.
Characteristic
· Available as Transmitter Version with Local Display
· Highly Precise and Fast Measurement of Dissolved CO2
· Several Short Measurement Cycles per Minute
· Short Response Time and Excellent Long-Term Stability
· Hygienic Execution and Full CIP Capability
· Easy Maintainable within a Few Minutes
· Outstanding Price-Performance-Ratio
Technical Data
CARBOTEC TR-PT
Measuring Range 0 - 10 g/l
Accuracy ± 0,05 g/l
Repeatability ± 0,01 g/l
Response Time ≤ 20 s
Pressure of Operation Max. 10 bar
Temperature of Operation - 10 - + 100 °C
Temperature Compensation Pt100
Material 1.4404/AISI 316L, EPDM (FDA), PTFE (FDA)
Connections Compatible to Varivent? Inline-Housings
DN65 - DN150;
others on request Input 6 x digital (24 VDC)
Output 3 x digital (24 VDC) & 2 x analog (4 - 20 mA)
Profibus DP Option
Enclosure Rating IP65
Power Supply 24 VDC
Consulting phone010-8243-3533
Duke. All rights reserved Beijing tech technology Co. Ltd. 京ICP備14007870號-1